SPECIFICATIONS RD1, RD2 |
RD3 | ||
120mm Display . . . . . Display Window Visability Update Rate Temperature Humidity Power Supply . PT200M/P/X & PT600R Indicators . Other Australian Brands . PC Mode . SPECIAL FEATURES Communications . Primary Port Formats . . . STRUCTURE Case Size . Weight Housing . . . Mountings . . APPROVALS Australia . EUROPE USA |
RD1 has flip-flop digits, RD2 has 'Day-Bright' LED's RD1 and RD2: Status annunciators for Motion, Centre of Zero and Net mode (when connected to PT indicators) 430mm x 100mm Up to 60m 10 updates per second -10 ~ 50°C 110 ~ 240V AC, 50 ~ 60 Hz, 25w AC Auto-detects all A, B, & C outputs Auto-detects most common models Addressable to accept conforming data . RS-232/422/485 - 2 wire (receive only) 20mA serial current loop wire (receive only) RS-422/485 - 4 wire (receive and transmit for networking) . 600mm(L) x 148mm(H) x 78mm(D) 3.4kg Sturdy aluminium extrusion, weatherproof sealing with laminated shatterproof glass window Fitted with top & bottom mounting clamps . . C-Tick (N2708) Complies with NSC S1/0 for auxiliary devices CE approved FCC approval pending. |
Display . Update Rate Temperature Humidity Power Supply . PT200M/P/X & PT600R Indicators . Communications Case Materials . . Dimensions . Options . Weight |
20mm LCD, 6 digits, LED backlighting. 10 updates per second -10 ~ 50°C 12~24VDC or 4x AA alkaline cells with optional desk mount. Auto-detects all A, B, & C outputs RS-232 - 2 wire (receive only) ABS Silicon Rubber, Nylon, Acrylic (no halogen used) 164x77x35 mm (as panel mount). Desk mount shell and battery compartment. 0.36kg |