The floating load cell module should pay attention to the level adjustment, including the level adjustment between the mounting plane of a single module and a set of floating load cell modules.
When welding, the sensor cannot pass the current. When welding the top plate, the ground wire should be connected to the scale body, and when welding the bottom plate, the ground wire should be connected to the foundation to prevent damage to the sensor.
Floating load cell module If there is a feed pipe on the scale body, it should be replaced with a hose, or make the connecting pipe as long as possible to prevent them from eating the real load of the sensor and causing errors.
A weight check table should be welded to the container for verification. There is generally no place to place weights on the container, and a platform needs to be welded to place weights. It is usually welded to the bottom of the container so that the weights can be placed up and down.
The junction box must be protected from moisture, and the excess holes must be plugged with sealing plugs. If the junction box is installed outdoors, a protection box must be added to prevent rain. In the use of the junction box due to moisture caused by the failure often occur, so we must pay enough attention to.